Sign In | Join Free | My portofva.com
China Labnovation Technologies, Inc. logo
Labnovation Technologies, Inc.
Labnovation Technologies,Inc.
Active Member

4 Years

Home > Hematology Analyzer Reagents >

Coulter GenS LH750 LH780 DXH800 Hematology Reagent

Labnovation Technologies, Inc.
Contact Now

Coulter GenS LH750 LH780 DXH800 Hematology Reagent

  • 1
  • 2

Brand Name : LABNOVATION

Certification : ISO13485, ISO9001,CE

Place of Origin : China

MOQ : 500 Pieces

Price : US$8-12/Pieces

Payment Terms : D/A, D/P, T/T

Supply Ability : 500000/Day

Delivery Time : 10 work day

Packaging Details : 20L, 50L,500ML

Model Number : L-8547196

Expiry : 24 Months

Usage : Medical, Clinical Experiments

Type : Hematology Reagent

High Light : Blood Test Reagents, Medical Lab Reagents

State : Liquid

Purity : >99%

Contact Now

Hematology Reagent For Coulter Gen.S , LH-750, LH-780, DXH-800 Analyzers High Quality Reagents

Intended Use

To be used for blood cell counting, sizing, and WBC, RET differentiation, hemoglobin determination on Coulter GEN.S , LH-750, LH-780, DxH-800 hematology analyzers. This product is for In Vitro Diagnostic Use only.

Procedures
  • Remove all the reagent aspiration tubes from the currently used reagent boxes
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put all the tubes into the boxes and/or bottles of Labnovation reagents.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Precautions
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

Specification

L-8547196 RET STAIN 380 ML
L-8547197 RET LYSE 1900 ML
L-8546983 LYSE DIFF 1 L
L-8546733 ISOTONIC DILUENT 20 L
L-8546930 E-CLEANER 5 L

KIT COMPOSITION

RET STAIN

New Methylene Blue 0.06%

RET LYSE Sulfuric Acid 0.15%
LYSE DIFF

Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%

ISOTONIC DILUENT

NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1%

E-CLEANER Buffer<0.3%, Proteolytic Enzyme<0.2%
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Coulter GenS LH750 LH780 DXH800 Hematology Reagent

APPLICABLE INSTUMENT

  • For use with Beckman coulter GEN.S , LH-750, LH-780, DxH-800 hematology analyzers.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand.

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

Product Tags:

DXH800 Hematology Reagent

      

LH780 Hematology Reagent

      

Coulter GenS Hematology Reagent

      
China Coulter GenS LH750 LH780 DXH800 Hematology Reagent wholesale

Coulter GenS LH750 LH780 DXH800 Hematology Reagent Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)