Sign In | Join Free | My portofva.com
China Labnovation Technologies, Inc. logo
Labnovation Technologies, Inc.
Labnovation Technologies,Inc.
Active Member

4 Years

Home > Influenza AB Test Kit >

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

Labnovation Technologies, Inc.
Contact Now

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

  • 1
  • 2

Brand Name : LABNOVATION

Model Number : LX-401401

Certification : ISO13485, ISO9001, CE

Place of Origin : China

MOQ : 10000

Price : US$0.9-2/Pcs

Payment Terms : D/A, D/P, T/T

Supply Ability : 500000/Day

Delivery Time : 5-7 work day

Packaging Details : Carton

Warranty : 18 Months

Test Speed : within 15 minutes

Storage : 2℃-30℃

Humidity : ≤60%

Storage Temp : 2-30℃

Total Accuracy : >90%

Contact Now

Rapid Test Kit COVID-19 Antigen And Influenza A/B Rapid Test Kit High Accuracy 20 Tests Rapid Test Kit


Intended Use
SARS-CoV-2 Antigen & influenza A/B Rapid Test Kit provideds a simple, rapid detection as an aid in the differential diagnosis of SARS-CoV-2 Antigen and Influenza A&B using nasal swab specimens. This easy-to-use product and rapid results can be used for the screening of early infected patients and asymptomatic patients. It also effective supplement for nucleic acid detection.
Specification

Item

Antigen test strip performance
against PCR

Influenza A test strip performance against PCR Influenza B test strip performance against PCR
Sensitivity 98.03% 93.3% 97.00%
Specificity 100.00% 91.00% 96.40%

Main Components

  • Test cassettes
  • Sample extraction buffers
  • Sample tubes
  • Swabs
  • Tube Stand
  • Instruction Manaual

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

Use Step

  • Take out the test cassette from the sealed pouch, place it on a clean and level surface with the sample port well up.
  • Apply 2 full drops of the treated sample (60μl-70μl) vertically into each of the two sample wells of the test cassette.

  • Observe the test results immediately within 15~20 minutes, the result is invalid over 20 minutes.

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

Interpretation Of Result

  • POSITIVE: The presence of T (T on nCoV /A or B on Flu) and C lines within the reaction window indicate a positive result on SARS-CoV-2 or Flu A and/or B infection or co-infection.

  • NEGATIVE: One colored line appears in the control region(C). No apparent colored line appears in the test region (T on nCoV /A or B on Flu). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

Feature

  • Specimen type: nasal swabs/oropharyngeal swabs
  • Rapid test, the test result is available within 15 min.
  • Read test results visually. Do not require test requirements.
  • Early detection of new Virus infection.
  • Simple operation and highly-efficient test.

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy

Principle

  • The SARS-CoV-2 Antigen & Influenza A/B Rapid Test Kit employs a lateral flow chromatographic technology to detect the presence of the nucleocapsid protein antigen directly from influenza A, influenza B, and SARS-CoV-2.
  • After the patient sample is collected and treated with the antigen extraction buffer, the viral nucleoproteins antigen will be exposed. Add the extracted specimen into the test cassette, the specimen will migrate forward along with the test strips through capillary effect. If Influenza A, Influenza B, SARS-CoV or SARS-CoV-2 viral antigen is present, they will be captured and detected on the T or A/B line, respectively on each test strips within 15 minutes from the addition of the samples, resulting in purplish red band on the test region, indicating a positive result. If the nucleocapsid protein antigen is not present or present at very low levels in the sample, there is no red line appears in “T” or "A/B" positions. The “Control Line” (C) is used for procedural control.
  • Control line should always appear if the test procedure is performed properly and the test reagents of control line are working.

FAQ

  • About MOQ?

We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.

  • What is your lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

  • Accept OEM or ODM order?

Yes, we accept both OEM and ODM for customers.

  • What are your terms of delivery?

We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.

  • Manufacturer or Trade Company?

We're Manufacturer.



Product Tags:

COVID 19 Antigen Influenza AB Test Kit

      

Influenza AB Test Kit 90% Accuracy

      

Nasal Swabs influenza a and b test kits

      
China Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy wholesale

Nasal Swabs COVID-19 Antigen Influenza AB Test Kit 90% Accuracy Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)